Aqua-Air Industries, Inc. Saturation Diving   Systems Division
3
Introduction
  • Aqua-Air Industries, Inc. welcomes you.  In order to meet the demands of the diving industry and to maintain the accelerated pace towards greater operational depth, we have utilized the knowledge and past experience of all our personnel to design and construct the Saturation Diving System that is safe, efficient and economical.


4
Saturation Diving Division Customers
  • Veolia ES (ONYX)
  • Superior Offshore
  • Oceaneering Int’l.
  • Con-Dive, LLC
  • S & J Diving
  • Oceanografia
  • Inspectronics
  • Global Diving & Salvage
  • Chet Morrison Contractors
5
Saturation System Division
Completed Projects
6
Item 6
7
Item 7
8
Item 8
9
Item 9
10
Item 10
11
Item 11
12
Item 12
13
Item 13
14
Item 14
15
Item 15
16
10 Man HRC
17
Item 17
18
"Electric Hot Water Unit for..."
  • Electric Hot Water Unit for Sat (Half). Heater unit is electrically powered and capable of heating seawater and freshwater with a flow of 6.5 GPM with 58 PSI (4 Bars) inlet water pressure.  It has a single boiler heat exchanger pressure vessel with over pressurization devices. CAT pump is incorporated to boost the hot water supply to the diver at 450 PSI (31 Bars).


19
Gas Storage Kelly Tubes
  • Unit Service Pressure - 3600 PSI
  • Total Water Volume –133.5 cu. ft.
  • Length - 34 ft.
  • Diameter –18 in.
  • Manifold - Each cylinder’s valve tied to central manifold with additional valve at each end
  • Helium – 29,391 cu.ft.@ 3600 PSI
  • Nitrogen – 30,060 cu.ft. @ 3600PSI
  • Air – 30,915 cu.ft. @ 3600 cu.ft. PSI
20
Gas Storage Kelly Tubes
  • Unit Service Pressure - 3185 PSI
  • Total Water Volume -267 cu. ft.
  • Length - 34 ft.
  • Diameter –18 in.
  • Manifold - Each cylinder’s valve tied to central manifold with additional valve at each end
  • Helium – 49,872 cu.ft.@ 3000 PSI
  • Nitrogen – 51,774 cu.ft. @ 3000PSI
  • Air – 53,124cu.ft. @ 3000 cu.ft. PSI
21
"“ORCA"
  • “ORCA”
22
System Layout at Facility
23
System Final Layout
24
System Actual Layout
25
Handling System
  • The handling system for the bell incorporates an “U" Frame  bell winch, power sheave, and guideline winch. The winches, the spool piece with hydraulic clamp and umbilical rollers are controlled from the bell control room. The system is designed with safety factors based on its rated capacity at rated speed. Structural design criteria involve dead, live, dynamic and other loads.
26
Handling System, (continued)
  • Additional the structural members are treated as stress components of the entire handling system. The power system and support equipment is designed for 100% of the designed load
27
1000 FT Bell
28
1000 FT DDC
29
Dive/Saturation Control  Module
30
Life Support Module No.1
31
Life Support Module No.2
32
Work Shop/Spare/ Electrical Distribution Module
33
Gas Storage Kelly Tubes
  • Unit Service Pressure - 3600 PSI
  • Total Water Volume-356 cu. ft.
  • Length - 34 ft.
  • Diameter –18 in.
  • Manifold - Each cylinder’s valve tied to central manifold with additional valve at each end
  • Helium – 78,376 cu.ft.@ 3600 PSI
  • Nitrogen – 80,160 cu.ft. @ 3600PSI
  • Air – 70,832 @ 3600 cu.ft. PSI
34
Saturation Diving Division
Projects
Under Construction
35
AAI’s New Systems
36
System Components
37
 
38
 
39
Gas Storage ASME Tube
Under Refurbishment
  • Unit Service Pressure - 3600 PSI
  • Total Water Volume – 60 cu. ft.
  • Length - 12 ft.
  • Diameter –30 in.
  • Manifold - Cylinder’s valve tied to central manifold with additional valve at each end
  • Helium – 13,209 cu.ft.@ 3600 PSI
  • Nitrogen – 13,510 cu.ft. @ 3600PSI
  • Air – 13,894 cu.ft. @ 3600 cu.ft. PSI
40
Design Concept
  • Hyperbaric Rescue Chamber (HRC) Control “Flyway” Module
41
 
42
HRC Control Room
  • The control room will have the following services included in the system:
  • 01)   Depth monitoring system.
  • 02)   Pressurization and vent.
  • 03)   Bib control panel
  • 04)   CO2 and O2 analyzer panel
  • 05)   Calibration gas panel
  • 06)   O2 injection panel
  • 07)   Temperature and humidity monitoring panel.
43
HRC Control Room (continued)
  • 08)   Communication control panel.
  • 09)   On-line gas storage panel (distribution).
  • ·        Pressurization.
  • ·        Bibs.
  • ·        Treatment mix.
  • 10)   Over pressurization relief system.
  • 11)   TV monitoring system.
  • 12)   Public Address system.
  • 13)   Two man self contained B/A set with hose line connections.
44
HRC Control Room (Continued)
  • 14)   Gas distribution marker boards.
  • 15)   LP compressor and gas compressor monitoring panel.
  • 16)   Electric distribution panel


45
Environmental Room
  • Potable Water System
  • The potable water system will supply hot and cold water at 103 psi (7 bar) over the working pressure in continuous operation and consist of two systems including:
  • 01)Two SS Steel receivers 600 psi working pressure.
  • 02)Two piston pumps with 500 psi working pressure each.
  • 03)Two pressure switches.
  • 04)Two pulse restrictors.
  • 05)Mounting rack.
  • 06)15 gallon hot water unit
46
Environmental Room (continued)
  • Treatment Rack
  • This rack will hold the treatment mix gas which includes (1) rack of 12 cylinders of 440 cu. ft. to 2400 psi each. The rack will have isolation valves and manifold and will be piped to the control room via HP manifold.


47
Environmental Room (continued)
  • Environmental Conditioning Unit
  • Chiller package Model OC-500R-H/C-ECU.
  • A completely packaged closed loop type cooler with the capacity to remove 60,000 BTU/Hr while re-circulating 50% water/glycol at -36°F in an 81° F    (-10°c in a 35°c) ambient. Cooler to consist of dual 7.5Hp air cooled conducing unit with full controls for automatic operation including:
  • 2) Digital temperature control units.


48
Environmental Room (continued)
  • 2) Direct expansion type evaporator.
  • 2) 316SS sump tank with filler/breather cap and level gauge for hot and cold systems
  • 2) Pumps with capacity of 10 gpm at 5 psi electric panel 480/440 Volt
  • 3 phase, 60 Hz.
  • 2) 3 kw heating capacity
  • 17)Solenoid  control valves operated by humidity/temperature  control in control room


49
Environmental Room (continued)
  • Sewage Tank
  • Volume tank rate at 450 PSI used as sanitary holding tank. Tank outfitted with valve controls and gauges for the discharging of sewage material.


  • HRC Umbilical
  • Length to be provided is 50 ft according to AAI specifications. Complete list of the services in the bundle will give full control of the HRC
50
Real Life
  •     Decades of experience combined with R&D and testing, have time and time again provided products and services invaluable to our customers worldwide. Other companies may imitate but cannot duplicate the quality and innovation Aqua-Air has contributed to the diving industry.
51
What This Means